Poulan Chainsaw Primer Bulb Not Working: [Proven Ways To Fix]

As a chainsaw owner, you know that a primer bulb that doesn’t work can be a major inconvenience. It can prevent you from starting your chainsaw, which can be a real pain when you’re in the middle of a project.

There are a few things that can cause a primer bulb to stop working, and it’s important to be able to diagnose the problem so that you can fix it quickly. In this guide, I’ll walk you through the steps of troubleshooting a Poulan chainsaw primer bulb that isn’t working. I’ll also provide some tips on how to prevent this problem from happening in the future.

By the end of this guide, you’ll be able to quickly and easily diagnose and fix a Poulan chainsaw primer bulb that isn’t working. So let’s get started!

Most Common Reasons Of Poulan Chainsaw Primer Bulb Not Working

Cracked Primer Bulb

The most common reason for a Poulan chainsaw primer bulb not working is a cracked bulb. This can be caused by a number of things, such as:

Overtightening the bulb: When you tighten the primer bulb, you should only do it until it is snug. If you overtighten it, you can crack the bulb.
Dropping the chainsaw: If you drop your chainsaw, it can cause the primer bulb to crack.
Excessive heat: If your chainsaw is exposed to excessive heat, it can cause the primer bulb to crack.

If you think your primer bulb is cracked, you can replace it with a new one. You can find replacement primer bulbs at most hardware stores.

Clogged Primer Bulb

Another common reason for a Poulan chainsaw primer bulb not working is a clogged bulb. This can be caused by:

Dirt: If dirt gets into the primer bulb, it can clog the small opening and prevent the bulb from working properly.
Gasoline: If gasoline gets into the primer bulb, it can also clog the opening and prevent the bulb from working properly.

If you think your primer bulb is clogged, you can try cleaning it with a small brush. If that doesn’t work, you can replace the bulb with a new one.

Damaged Primer Bulb

A Poulan chainsaw primer bulb can also be damaged by:

Chemicals: If chemicals are spilled on the primer bulb, they can damage the rubber and cause the bulb to leak.
UV rays: If your chainsaw is exposed to UV rays for long periods of time, it can damage the rubber and cause the bulb to leak.

If you think your primer bulb is damaged, you should replace it with a new one.

Incorrect Priming Technique

Finally, a Poulan chainsaw primer bulb can also not work properly if you are not priming the chainsaw correctly. To prime the chainsaw, you should:

1. Hold the chainsaw with the handle pointed up.
2. Squeeze the primer bulb until it is firm.
3. Release the primer bulb and pull the starter rope until the engine starts.

If you are not priming the chainsaw correctly, it will not start.

How to Troubleshoot: Poulan Chainsaw Primer Bulb Not Working

Symptoms of a Poulan Chainsaw Primer Bulb Not Working

There are a few symptoms that can indicate that your Poulan chainsaw primer bulb is not working properly. These include:

The chainsaw won’t start, even after priming it
The chainsaw starts but dies after a few seconds
The chainsaw starts but runs rough
The chainsaw smokes excessively

Troubleshooting a Poulan Chainsaw Primer Bulb

If you’re experiencing any of the symptoms listed above, it’s likely that your Poulan chainsaw primer bulb is not working properly. To troubleshoot the problem, follow these steps:

1. Check the primer bulb for leaks. Look for any cracks or damage to the bulb. If you find a leak, replace the bulb.
2. Check the primer bulb for clogs. Remove the primer bulb from the chainsaw and inspect it for any clogs. If you find a clog, clean it out with a small brush or needle.
3. Test the primer bulb. Reconnect the primer bulb to the chainsaw and prime it several times. If the chainsaw still won’t start, replace the primer bulb.

Replacing the Primer Bulb on a Poulan Chainsaw

Replacing the primer bulb on a Poulan chainsaw is a relatively simple task. To do this, follow these steps:

1. Turn off the chainsaw and disconnect the spark plug wire.
2. Remove the air filter cover.
3. Locate the primer bulb. The primer bulb is a small, cylindrical-shaped object located on the side of the carburetor.
4. Unscrew the primer bulb from the carburetor.
5. Install the new primer bulb. Make sure that the new primer bulb is the correct size and type for your chainsaw.
6. Reattach the air filter cover.
7. Reconnect the spark plug wire.

Preventing Primer Bulb Problems

The best way to prevent primer bulb problems is to keep your chainsaw clean and well-maintained. Here are a few tips to help you keep your primer bulb in good working order:

Prime the chainsaw before each use. This will help to prevent the primer bulb from drying out.
Clean the primer bulb regularly. Use a small brush or needle to clean out any dirt or debris that may be clogging the bulb.
Replace the primer bulb as needed. If the primer bulb is damaged or worn out, replace it with a new one.

By following these tips, you can help to ensure that your Poulan chainsaw primer bulb will last for many years to come.

Also Check: Poulan Pro Chainsaw Chain Oiler Not Working

FAQs: Poulan Chainsaw Primer Bulb Not Working

Why is my Poulan chainsaw primer bulb not working?

There are a few reasons why your Poulan chainsaw primer bulb might not be working. Here are the most common:

The bulb is clogged. The primer bulb can become clogged with dirt, dust, or other debris. This can prevent the bulb from filling with fuel, which will prevent the chainsaw from starting.
The bulb is damaged. The primer bulb can be damaged if it is dropped or if it is subjected to excessive heat. If the bulb is damaged, it will not be able to fill with fuel properly.
The fuel line is kinked or blocked. The fuel line can become kinked or blocked, which will prevent fuel from flowing to the carburetor. This can also prevent the chainsaw from starting.
The carburetor is dirty or clogged. The carburetor can become dirty or clogged, which will prevent it from properly mixing air and fuel. This can also prevent the chainsaw from starting.

How do I fix a Poulan chainsaw primer bulb that is not working?

To fix a Poulan chainsaw primer bulb that is not working, you will need to:

1. Check the bulb for clogs. Remove the primer bulb from the chainsaw and inspect it for clogs. If the bulb is clogged, you can clean it with a clean rag or a small brush.
2. Check the bulb for damage. Inspect the bulb for cracks or tears. If the bulb is damaged, you will need to replace it.
3. Check the fuel line for kinks or blockages. Inspect the fuel line for kinks or blockages. If the fuel line is kinked or blocked, you will need to straighten it out or clear the blockage.
4. Clean the carburetor. If the carburetor is dirty or clogged, you will need to clean it. You can clean the carburetor yourself or you can take it to a qualified service technician.

What are the symptoms of a Poulan chainsaw primer bulb that is not working?

The symptoms of a Poulan chainsaw primer bulb that is not working can include:

The chainsaw will not start.
The chainsaw will start but will not run smoothly.
The chainsaw will run but will stall frequently.
The chainsaw will smoke excessively.

What are the dangers of using a Poulan chainsaw with a primer bulb that is not working?

There are a few dangers of using a Poulan chainsaw with a primer bulb that is not working. These dangers include:

The chainsaw may not start, which could lead to injury.
The chainsaw may start but will not run smoothly, which could lead to injury.
The chainsaw may run but will stall frequently, which could lead to injury.
The chainsaw may smoke excessively, which could lead to a fire.

How can I prevent my Poulan chainsaw primer bulb from not working?

To prevent your Poulan chainsaw primer bulb from not working, you can:

Keep the bulb clean and free of clogs.
Inspect the bulb regularly for damage.
Keep the fuel line free of kinks or blockages.
Clean the carburetor regularly.
Store the chainsaw in a cool, dry place.

 

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *